On-site air monitor PTM600-S product introduction:
1. Explosion-proof certification, explosion-proof level Ex ib IIC T6 Gb/Ex i bD 21 T80℃
2. Air temperature sensor range ≥-40~60℃, resolution ≤0.1℃, accuracy ≤±0.2°C(25℃);
3. Air humidity sensor range ≥0~100%RH, resolution ≤0.1 %RH, accuracy ≤±3%RH(60% 25℃);
4. Wind speed sensor range ≥0~60m/s, resolution ≤0.1m/s, accuracy ≤±0.3m/s;
5. Wind sensor range; 0-360°, resolution ≤1°, accuracy ≤±0.5%;
6. Noise sensor range ≥30~120dB, resolution 1dB, accuracy ≤±0.5dB;
7. PM2.5 range ≥0~1000ug/m3, resolution ≤1ug/m3, accuracy ≤±10%;
8. P M10 range ≥0~1000ug/m3, resolution ≤1ug/m3, accuracy ≤±10%
9, air pressure range ≥0~120kPa, resolution ≤0.1kPa, accuracy ≤±0.15kPa@25% 75kPa;
10. Host data collector multi-channel data collector, can be automatically recorded, recording interval can be set according to customer needs, with 220V and 12V power supply;
11. Supply Electricity method 220V power supply system city power AC;
12. Communication mode GPRS wireless transmission free monitoring cloud platform/free docking government platform;
13. Lutter box placement noise, PM2.5, PM10, temperature and humidity, atmospheric pressure, accessories There are two ways to choose from the bracket 3m upright and tripod bracket;
14. With permanent logo and product data identification.
On-site air monitor PTM600-S
1. Provide test reports from national testing institutions or products issued by third-party testing institutions with CNAS/CMA qualification certification Test report; explosion-proof certification, explosion-proof level Ex ib IIC T6 Gb/Ex ibD 21 T80℃
2. Air temperature sensor range ≥-40~60℃, resolution ≤0.1℃, accuracy ≤±0 .2°C(25℃);
3. Air humidity sensor range ≥0~100%RH, resolution ≤0.1%RH, accuracy ≤±3%RH(60% 25℃);
4, wind speed sensor range ≥0~60m/s, resolution ≤0.1m/s, accuracy ≤±0.3m/s;
5. Wind sensor range; 0-360°, resolution ≤1°, accuracy ≤±0.5%;
6. Noise sensor range ≥30~120dB, resolution 1dB, accuracy ≤±0.5dB;
7. PM2.5 range ≥0~1000ug/m3, resolution ≤1ug/m3, accuracy ≤±10%;
8, PM10 range ≥0~1000ug/m3, resolution ≤1ug/m3, accuracy ≤±10%
9, air pressure range ≥0~120kPa, score Recognision rate ≤0.1kPa, accuracy ≤±0.15kPa@25% 75kPa;
10, host data collector multi-channel data collector, can be recorded automatically, the recording interval can be set according to customer needs, with 220V and 1 2V power supply;
11. Power supply method 220V power supply system AC power;
12. Communication mode GPRS wireless transmission free monitoring cloud platform/free docking government platform;
13. Lument box placement noise, PM2.5, PM10, temperature and humidity, atmospheric pressure, accessories There are two ways to choose from the equipment bracket 3m vertical pole and tripod bracket;
14, with permanent logo and product data identification.