Shenzhen Eranntex Electronics Co., Ltd

首页> Product>Control Alarm

Gas alarm controller MIC2000

Detection Method:

Detection Gas: Two-in-one gas detector 4-in-one gas detector Four-in-one detector Four-in-one gas detector Multi-gas detector Multi-in-one gas detector Multifunctional gas detector Laser dust PM2.5 Carbon dioxide (infrared) CO2 Carbon dioxide (laser TDLAS) CO2 Combustible instrument Ex Combustible (Infrared) Ex Methane CH4 Methane (infrared) CH4 Methane (laser TDLAS) CH4 Ethane (infrared) C2H6 Ethane Identifer (Laser) C2H6 Propane (infrared) C3H8 Non-methane total hydrocarbon CxHy Carbon monoxide CO Carbon monoxide (infrared) CO Hydrogen sulfide H2S Hydrogen sulfide (TDLAS tunable diode laser) H2S Oxygen O2 Nitrogen N2Ammonia NH3 Chlorine CL2 Hydrogen H2 Helium He Argon Ar Formaldehyde CH2O Ozone O3 Nitric oxide NO Nitrogen dioxide NO2 Nitrogen oxide NOX Sulfur dioxide SO2 Epoxy ethane ETO Ethane oxide (infrared) C2H4O Hydrogen phosphide PH3 Hydrogen chloride HCL Hydrogen cyanide HCN Light gas COCL2 CHLORINE DIOXIDE CLO2 Silane SiH4 Bromomethane (infrared) CH3Br Bromomethane (PID) CH3Br Thioyl fluorine (infrared) SO2F2 Fluorine gas F2 Hydrogen fluoride HF Hydrogen bromide HBr Ethylborane B2H6 Hydrogen arsenide AsH3 Germanium Alkane GeH4 Biamine N2H4 N2H4 C2H8N2 Nitrogen tetraoxide N2O4 Nitrogen trichloride NCL3Tert-butyl thiol TBM Phosphorus pentafluoride PF5 Boron trichloride BCL3 Phosphorus trichloride PCL3 Trichlorophosphate POCL3 Phosphorus trifluoride PF3 Boron trifluoride BF3 Azaic acid HN3 Methyl sulfide C2H6S Dimethyl sulfate C2H6O4S Acetonitrile CH3CN Acetic acid C2H4O2 Acetic acid C2H4O2 Methyl acrylate MA Ethyl acrylate EA Dimethyldisulfide C2H6S2 Dimethyl ether C2H6O Dimethyl disulfide C2H6S2 Dichlorosilane SiH2Cl2 Chlorosilane SiH3Cl Tetrahydrothiophene THT Bromine Br2 Acetylene (infrared) C2H2 Acetylene C2H2 Carbon disulfide CS2 Carbon disulfide (infrared) CS2 Acrylonitrile C3H3N Butone MEK Acetone MDKAcetone (infrared) C3H6O Sulfur hexafluoride (infrared) SF6 Ethylene C2H4 Ethylene (infrared) C2H4 Isopropyl alcohol (infrared) C3H8O Ethanol C2H6O Ethanol (infrared) C2H6O Methanol CH4O Methanol (infrared) CH4O Methamine CH5N Methanol CH3SH Vinyl chloride C2H3CL Vinyl chloride (infrared) C2H3CL Trichloroethylene C2HCL3 Tetrachloroethylene C2CL4 Chloromethane (infrared) CH3CL Dichloroethane (infrared) C2H4CL2 Dichloromethane (infrared) CH2CL2 Trichloromethane (infrared) CHCL3 Laughing gas (infrared) N2O Nitrogen trifluoride NF3 Nitrogen trifluoride (infrared) NF3 Hydrogen peroxide H2O2 Styrene (PID) C8H8Tetrahydrofuran (PID) THF TVOC (PID) TVOC TVOC (infrared) TVOC VOC (PID) VOC (infrared) Benzene (PID) C6H6 Toluene (PID) C7H8 Toluene (infrared) C7H8 Xylene (PID) C8H10 Xylene (infrared) C8H10 PID gas STINKY OU Diesel (infrared) diesel Aviation kerosene (infrared) JET Btane (infrared) C4H10 Isobutane (infrared) C4H10 Pentane (infrared) C5H12 Cyclopentane (infrared) C5H10 Hexane (infrared) C6H14 Acrylic (infrared) C3H6 Methyl ketone (infrared) C4H8O Carbonyl sulfur (infrared) COS Heptafluoropropane (infrared) C3HF7Refrigerant, refrigerant (infrared) R116 Freon CFC Refrigerant CFC

(Over 500 detectable gas types available, please consult our customer service)

Customization: Supports on-demand customization

Hotline: 13480931872

Get Quote Download Manual Back to List

Product ParametersCommon Gas ListProduct IntroductionProduct Details

Item Parameter
Detection Gas Can connect various gas detectors, temperature and humidity transmitters, pressure transmitters, wind speed transmitters, dust detectors and other RS4855 or 4-20mA signals
Product Features 1. Cost-effective
2. Chinese and English can be selected
3. Connect 4-20mA and RS485 signals at the same time, and can output 4-20mA and RS485
4. Support wireless transmission
Detection Range
Resolution
Typical Accuracy ±0.1%FS
Detection Method
Display 3.5-inch high-definition color screen
Power Supply AC 180~240V 50H/60H
Maximum Power Consumption 2.5W/road
Operating Environment -20℃~+70℃
0~95%RH, used in non-condensation occasions
Data Storage Large-capacity storage
Printing Function Can be customized
Signal Output RS485 (standard MODBUS protocol), optional: 4-20mA (4-way, 8-way), wireless (4G/3G/433M/LoRa/Zigbee), Ethernet interface output, etc.
Alarm Method Sound and light alarm, three-level alarm, each loop can set the high and low limit alarm values separately, and each loop can bind the three-way relay linkage output.
Fall Alarm Can be customized
Wireless Transmission Ethernet transmission or wireless transmission function (2 kilometers, 5 kilometers, unlimited distance optional), upload data to the monitoring center, environmental protection bureau, other monitoring equipment through 2-core data cable (wired transmission), local area network, Internet or wireless transmission network, and then display the data through the upper computer software, Store, analyze, or use communication protocols to customize and read data
Dimensions: L*W*H 260*90*330mm (L×W×H)
Weight About 3.8Kg
Protection Level IP 65
Standard Accessories Instruments, instructions, warranty cards, qualification certificates
Optional Accessories Choose according to customer needs
Partial list of detectable gases:
Detect gasesRangeMaximum allowable error valueMinimum readingResponse time T90
Combustible Gas (EX)0-100%LEL<±2%(F.S)0.1%LEL≤10 seconds
Combustible Gas (EX)0-100%Vol<±2%(F.S)0.1%Vol≤10 seconds
Methane (CH4)0-100%LEL<±2%(F.S)0.1%LEL≤10 seconds
Methane (CH4)0-100%Vol<±2%(F.S)0.1%Vol≤10 seconds
Oxygen (O2)0-30%Vol<±2%(F.S)0.01%Vol≤10 seconds
Oxygen (O2)0-100%Vol<±2%(F.S)0.01%Vol≤10 seconds
Oxygen (O2)0-5000ppm<±2%(F.S)1ppm≤30 seconds
Nitrogen (N2)0-100%Vol<±2%(F.S)0.01%Vol≤10 seconds
Carbon monoxide (CO)0-100ppm<±2%(F.S)0.1ppm≤25 seconds
Carbon monoxide (CO)0-1000ppm<±2%(F.S)0.1ppm≤25 seconds
Carbon monoxide (CO)0-2000ppm<±2%(F.S)0.1ppm≤25 seconds
Carbon monoxide (CO)0-20000ppm<±2%(F.S)1ppm≤25 seconds
Carbon monoxide (CO)0-100000ppm<±2%(F.S)1ppm≤25 seconds
Carbon dioxide (CO2)0-500ppm<±2%(F.S)1ppm≤20 seconds
Carbon dioxide (CO2)0-2000ppm<±2%(F.S)1ppm≤20 seconds
Carbon dioxide (CO2)0-5000ppm<±2%(F.S)1ppm≤20 seconds
Carbon dioxide (CO2)0-50000ppm<±2%(F.S)1ppm≤30 seconds
Carbon dioxide (CO2)0-20%Vol<±2%(F.S)0.01%Vol≤30 seconds
Carbon dioxide (CO2)0-100%Vol<±2%(F.S)0.01%Vol≤30 seconds
Formaldehyde (CH2O)0-10ppm<±2%(F.S)0.001ppm≤30 seconds
Formaldehyde (CH2O)0-10ppm<±2%(F.S)0.01ppm≤30 seconds
Formaldehyde (CH2O)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Formaldehyde (CH2O)0-5000ppm<±2%(F.S)1ppm≤50 seconds
Ozone (O3)0-1ppm<±2%(F.S)0.001ppm≤20 seconds
Ozone (O3)0-5ppm<±2%(F.S)0.001ppm≤20 seconds
Ozone (O3)0-50ppm<±2%(F.S)0.01ppm≤20 seconds
Ozone (O3)0-100ppm<±2%(F.S)0.01ppm≤20 seconds
Ozone (O3)0-2000ppm<±2%(F.S)0.1ppm≤30 seconds
Ozone (O3)0-30000ppm<±2%(F.S)1ppm≤30 seconds
Hydrogen sulfide (H2S)0-10ppm<±2%(F.S)0.001ppm≤30 seconds
Hydrogen sulfide (H2S)0-50ppm<±2%(F.S)0.01ppm≤30 seconds
Hydrogen sulfide (H2S)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Hydrogen sulfide (H2S)0-2000ppm<±2%(F.S)0.1ppm≤30 seconds
Hydrogen sulfide (H2S)0-10000ppm<±2%(F.S)1ppm≤45 seconds
Sulfur dioxide (SO2)0-10ppm<±2%(F.S)0.001ppm≤30 seconds
Sulfur dioxide (SO2)0-20ppm<±2%(F.S)0.01ppm≤30 seconds
Sulfur dioxide (SO2)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Sulfur dioxide (SO2)0-500ppm<±2%(F.S)0.1ppm≤30 seconds
Sulfur dioxide (SO2)0-2000ppm<±2%(F.S)0.1ppm≤30 seconds
Sulfur dioxide (SO2)0-10000ppm<±2%(F.S)1ppm≤30 seconds
Nitric oxide (NO)0-10ppm<±2%(F.S)0.001ppm≤30 seconds
Nitric oxide (NO)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Nitric oxide (NO)0-2000ppm<±2%(F.S)0.1ppm≤30 seconds
Nitric oxide (NO)0-5000ppm<±2%(F.S)1ppm≤30 seconds
Nitrogen dioxide (NO2)0-10ppm<±2%(F.S)0.001ppm≤25 seconds
Nitrogen dioxide (NO2)0-100ppm<±2%(F.S)0.01ppm≤25 seconds
Nitrogen dioxide (NO2)0-1000ppm<±2%(F.S)0.1ppm≤30 seconds
Nitrogen dioxide (NO2)0-5000ppm<±2%(F.S)1ppm≤30 seconds
Nitrogen oxides (NOX)0-10ppm<±2%(F.S)0.001ppm≤30 seconds
Nitrogen oxides (NOX)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Nitrogen oxides (NOX)0-2000ppm<±2%(F.S)0.1ppm≤30 seconds
Nitrogen oxides (NOX)0-5000ppm<±2%(F.S)1ppm≤30 seconds
Chlorine (CL2)0-10ppm<±2%(F.S)0.001ppm≤30 seconds
Chlorine (CL2)0-20ppm<±2%(F.S)0.01ppm≤30 seconds
Chlorine (CL2)0-200ppm<±2%(F.S)0.1ppm≤30 seconds
Chlorine (CL2)0-2000ppm<±2%(F.S)0.1ppm≤30 seconds
Ammonia (NH3)0-50ppm<±2%(F.S)0.01ppm≤30 seconds
Ammonia (NH3)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Ammonia (NH3)0-1000ppm<±2%(F.S)0.1ppm≤30 seconds
Ammonia (NH3)0-5000ppm<±2%(F.S)1ppm≤30 seconds
Ammonia (NH3)0-100%LEL<±2%(F.S)0.1%LEL≤10 seconds
Hydrogen (H2)0-100%LEL<±2%(F.S)0.1%LEL≤10 seconds
Hydrogen (H2)0-1000ppm<±2%(F.S)0.1ppm≤30 seconds
Hydrogen (H2)0-20000ppm<±2%(F.S)1ppm≤30 seconds
Hydrogen (H2)0-40000ppm<±2%(F.S)1ppm≤30 seconds
Hydrogen (H2)0-100%Vol<±2%(F.S)0.01%Vol≤20 seconds
Helium (He)0-100%Vol<±2%(F.S)0.01%Vol≤20 seconds
Argon (Ar)0-100%Vol<±2%(F.S)0.01%Vol≤20 seconds
Xenon (Xe)0-100%Vol<±2%(F.S)0.01%Vol≤20 seconds
Hydrogen cyanide (HCN)0-30ppm<±2%(F.S)0.01ppm≤30 seconds
Hydrogen cyanide (HCN)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Hydrogen chloride (HCL)0-20ppm<±2%(F.S)0.01ppm≤30 seconds
Hydrogen chloride (HCL)0-200ppm<±2%(F.S)0.1ppm≤30 seconds
Phosphine (PH3)0-5 ppm<±2%(F.S)0.001ppm≤30 seconds
Phosphine (PH3)0-25 ppm<±2%(F.S)0.01ppm≤30 seconds
Phosphine (PH3)0-2000 ppm<±2%(F.S)1ppm≤30 seconds
Chlorine dioxide (CLO2)0-1ppm<±2%(F.S)0.001ppm≤30 seconds
Chlorine dioxide (CLO2)0-10ppm<±2%(F.S)0.01ppm≤30 seconds
Chlorine dioxide (CLO2)0-200ppm<±2%(F.S)0.01ppm≤30 seconds
Ethylene oxide (ETO)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Ethylene oxide (ETO)0-1000ppm<±2%(F.S)0.1ppm≤30 seconds
Ethylene oxide (ETO)0-100%LEL<±2%(F.S)1%LEL≤30 seconds
Phosgene (COCL2)0-1ppm<±2%(F.S)0.001ppm≤20 seconds
Phosgene (COCL2)0-50ppm<±2%(F.S)0.01ppm≤20 seconds
Silane (SiH4)0-1ppm<±2%(F.S)0.001ppm≤30 seconds
Silane (SiH4)0-50ppm<±2%(F.S)0.01ppm≤30 seconds
Fluorine (F2)0-1ppm<±2%(F.S)0.001ppm≤30 seconds
Fluorine (F2)0-10ppm<±2%(F.S)0.01ppm≤30 seconds
Fluorine (F2)0-50ppm<±2%(F.S)0.01ppm≤30 seconds
Hydrogen fluoride (HF)0-10ppm<±2%(F.S)0.01ppm≤30 seconds
Hydrogen fluoride (HF)0-50ppm<±2%(F.S)0.01ppm≤30 seconds
Hydrogen bromide (HBr)0-50ppm<±2%(F.S)0.01ppm≤30 seconds
Diborane (B2H6)0-10ppm<±2%(F.S)0.001ppm≤30 seconds
Arsine (AsH3)0-1ppm<±2%(F.S)0.001ppm≤30 seconds
Arsine (AsH3)0-10ppm<±2%(F.S)0.01ppm≤30 seconds
Arsine (AsH3)0-50ppm<±2%(F.S)0.01ppm≤30 seconds
Germane (GeH4)0-2ppm<±2%(F.S)0.001ppm≤30 seconds
Germane (GeH4)0-20ppm<±2%(F.S)0.01ppm≤30 seconds
Hydrazine (N2H4)0-1ppm<±2%(F.S)0.001ppm≤30 seconds
Hydrazine (N2H4)0-300ppm<±2%(F.S)0.1ppm≤30 seconds
Tetrahydrothiophene (THT)0-100mg/m3<±2%(F.S)0.01 mg/m3≤60 seconds
Bromine (Br2)0-10ppm<±2%(F.S)0.001ppm≤30 seconds
Bromine (Br2)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Bromine (Br2)0-2000ppm<±2%(F.S)1ppm≤30 seconds
Acetylene (C2H2)0-100%LEL<±2%(F.S)0.1%LEL≤30 seconds
Acetylene (C2H2)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Acetylene (C2H2)0-1000ppm<±2%(F.S)0.1ppm≤30 seconds
Ethylene (C2H4)0-100%LEL<±2%(F.S)0.1%LEL≤30 seconds
Ethylene (C2H4)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Ethylene (C2H4)0-2000ppm<±2%(F.S)0.1ppm≤30 seconds
Acetaldehyde0-10ppm<±2%(F.S)0.01ppm≤30 seconds
Ethanol (C2H6O)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Ethanol (C2H6O)0-2000ppm<±2%(F.S)1ppm≤30 seconds
Methanol (CH4O)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Methanol (CH4O)0-2000ppm<±2%(F.S)1ppm≤30 seconds
Carbon disulfide (CS2)0-50ppm<±2%(F.S)0.01ppm≤30 seconds
Carbon disulfide (CS2)0-5000ppm<±2%(F.S)0.01ppm≤30 seconds
Acrylonitrile (C3H3N)0-50ppm<±2%(F.S)0.01ppm≤30 seconds
Acrylonitrile (C3H3N)0-2000ppm<±2%(F.S)1ppm≤30 seconds
Methylamine (CH5N)0-50ppm<±2%(F.S)0.01ppm≤30 seconds
Iodine (I2)0-50ppm<±2%(F.S)0.01ppm≤30 seconds
Styrene (C8H8)0-200ppm<±2%(F.S)0.1ppm≤30 seconds
Styrene (C8H8)0-5000ppm<±2%(F.S)1ppm≤30 seconds
Vinyl chloride (C2H3Cl)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Trichloroethylene (C2HCl3)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Tetrachloroethylene (C2Cl4)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Nitrous oxide (N2O)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Nitrogen trifluoride (NF3)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Hydrogen peroxide (H2O2)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Methyl bromide (CH3Br)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Methyl bromide (CH3Br)0-30000ppm<±2%(F.S)1ppm≤30 seconds
Methyl bromide (CH3Br)0-200g/m3<±2%(F.S)0.1g/m3≤30 seconds
Sulfuryl fluoride (SO2F2)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Sulfuryl fluoride (SO2F2)0-5000ppm<±2%(F.S)1ppm≤30 seconds
Sulfuryl fluoride (SO2F2)0-10000ppm<±2%(F.S)1ppm≤30 seconds
Benzene (C6H6)0-10ppm<±2%(F.S)0.01ppm≤30 seconds
Benzene (C6H6)0-100ppm<±2%(F.S)0.01ppm≤30 seconds
Benzene (C6H6)0-2000ppm<±2%(F.S)1ppm≤30 seconds


Gas Alarm Controller MIC2000 Overview:

Gas alarm controller is a gas concentration monitoring and leakage Centralized alarm controller, the power supply is directly supplied by the mains power grid or the battery. This alarm controller receives RS485 signals and 4-20mA. For the time being, it can only receive the RS485 signal output by the company's new online detector. If you need to access the standard RS485 signal of other manufacturers, please contact our company for confirmation.A gas alarm controller can be connected to 120 bus RS485 output gas detectors and 8 4-20mA output gas detectors, and more input channels can be customized.


Gas Alarm Controller MIC2000 Features:

●3.5-inch high-definition color screen display, Chinese and English operation interface can be switched (default Chinese interface).

● It can connect various gas detectors, temperature and humidity transmitters, pressure transmitters, wind speed transmitters, dust detectors and other 4-20mA signals.

●Units can be selected: PPM, LEL%, Vol%, mg/m3, ug/L, PPHM, ℃, RH%, Pa, kg, PSI, m/s

● 4-20mA and RS485 can be input at the same time; data output supports standard MODBUS protocol optional: 8-way 4-20mA output, Ethernet module, upper computer monitoring software, RS485/RS232 converter, USB-RS232 connection cable (computers without serial ports need Optional this item)

● Modular structure design, the standard channel is 1 channel (up to 32 channels) 4-20mAInput signal, 255 RS485 input signals can be connected at the same time, and more channel input signals can be customized. , controllers can communicate with each other.

● The gas alarm controller has a data recording function, standard large-capacity storage, and a larger capacity can be customized. The storage time interval can be set arbitrarily to record time, concentration value, alarm information, etc. You can set to record real-time concentration or only record alarm information. The default setting is only to record alarm information. Support this machine to view all records, selectively view records, and delete records.

● Three display modes can be switched: each screen displays 6 channels of concentration, large fonts display the concentration of a single channel, real-time curve, each channelAutomatic cycle or manual loop can be switched, you can set whether to display the maximum value, minimum value, gas name, and view the history curve.

● The gas alarm controller is connected to the computer monitoring function, which can be connected to the computer to continuously monitor the real-time concentration 24 hours a day through the upper computer software, automatically store data on the computer, computer alarm (requires dubbing box), or read a probe through the upper computer software or All the records stored in the probe can be analyzed for data, which can display the maximum value, minimum value, average value, historical curve, real-time curve and other functions, and can export or print data

● Gas alarm controller remote transmission function, the controller can The real-time concentration of the probe is through the wire (within 2000 meters).

● Optional Ethernet transmission or wireless transmission function (2 km, 5 km, unlimited distance optional), upload data to the monitoring center, environmental protection bureau, and other monitoring through a 2-core data cable (wired transmission), local area network, Internet or wireless transmission network Equipment, and then through the upper computer software Display, store, analyze data, or use communication protocols to customize and read data.


<Gas Alarm Controller MIC2000 Display Interface:


image. png

Gas Alarm Controller MIC2000 Physical Picture:



image.pngimage.png

Gas Alarm Controller MIC2000 Optional Accessories:


image.png



Product HighlightsNew process formula enhances performance to meet stricter application requirements

500+ Detectable Gases

500+ Detectable Gases

Customize according to requirements 1-18 typesDetecting gas combinations

← Swipe left/right to view full content →

Complete Certifications, Reliable Quality

Trusted Manufacturer

Trusted Manufacturer

Wide Applications Across 20+ Industries

Trusted by 5000+ Industry Leaders

Service Guarantee

19+ Years of Industry-leading Brand

Eranntian, founded in 2006, is a national high-tech enterprise integrating design, R&D, production and sales. Our R&D team includes over 30 senior engineers with strong development capabilities, investing over 17% of annual revenue in technological innovation. We maintain long-term collaborations with 14 universities including Tsinghua University, Sichuan University, Xi'an Jiaotong University, Qingdao University of Technology, and Central South University.

  • 2006

    Eranntian established

  • 30+

    Senior R&D engineers

  • 14

    Partner universities

  • 100+

    Patents & achievements

Strong Production Capacity Ensures Fast Delivery

Application CasesMore+

Professional engineer

24-hour online serviceSubmit your needs and quickly recommend the right products for you

13480931872