Shenzhen Eranntex Electronics Co., Ltd

Gas Online Monitoring System Precision Storage Tank Ammonia Sulfur

1. Project Background


Keywords: Retention Pond, Hydrogen Sulfide, Ammonia, Temperature


Monitor ammonia and hydrogen sulfide levels, as well as temperature, within the retention pond.


Ambient temperature, high humidity (gas drawn from the retention pond contains some moisture), normal pressure, dust-free environment,


H₂S: 0–25 ppm


NH₃: 0-25 ppm


Temperature: -40°C to +120°C (actual gas temperature is ambient)


Testing Purpose: To verify the effectiveness of the client's own equipment in purifying hydrogen sulfide and ammonia. Results must be displayed to two decimal places.


2. Solution


Use a simple pre-treatment device to filter out moisture from the gas before measuring its concentration.


Pump-drawn system: gas from the retention pond is drawn through a pipeline for testing.


The product is installed outdoors with a stainless steel housing and an IP67 protection rating.


3. Product Configuration


Product Model: TH1000-B-YP


Detected gases: ammonia (NH₃), hydrogen sulfide (H₂S), and temperature


Detection range/resolution/detection principle:


NH₃: 0–25 ppm, 0.01 ppm, electrochemical sensor with hydrogen sulfide interference resistance;


H₂S: 0–25 ppm, 0.01 ppm, electrochemical sensor;


Temperature: -40°C to +70°C, 0.1°C, capacitive sensor;


Equipped with an instrument housing made of S304 material, with a thickness of no less than 1.5 mm.


Includes a 10-meter flexible hose for connecting to ductwork and instruments,


Features an NPT 1/4-8 connector (S304).


Instrument protection rating: IP67.


4. On-site Photos


图片3.png


Related Cases

Professional engineer

24-hour online serviceSubmit your needs and quickly recommend the right products for you

13480931872