Automatic monitoring system of garbage gas-TH3000-4
Cooperative Customer:
Changchun Environmental Engineering Co., Ltd.
Project Name:
Garbage Gas Automatic Monitoring Department Tong
Project background:
On the garbage pile monitoring well gas discharge summary pipe; garbage gas automatic monitoring system CH4, CO2, H2S, O2, four-component gas analysis instrument; methane range 0-15%vol, Oxygen 0-30%vol, carbon dioxide 0-30%vol, hydrogen sulfide 0-500ppm.
The three units are two to detect 5 points, and one detects 6 points, with its own gas line switching system, which can realize gas line control and detection data display in the remote plc cabinet, and transmit the signal 4-20ma.
It can meet the distance of 150 meters from the detection point from the farthest pipeline of the detector, and it is required to indicate the flow rate of the sampling pump.
Clean with compressed air backblow, give the pressure required for the compressed air source.
Outdoor cabinet explosion-proof, indicate the explosion-proof level.
Application products:
TH3000-4 (outdoor explosion-proof type)
Detection gas: methane CH4, carbon dioxide CO2, hydrogen sulfide H2S, oxygen O 2
Detection range/disparation rate/detection principle:
CH4:0-15%VOL, 0.01%VOL, original imported high-precision infrared principle sensor;
CO2:0-30%VOL,0.01%VOL, original imported high Precision infrared principle sensor;
H2S: 0-500PPM, 0.1PPM, original imported high-performance electrochemical principle sensor;
O2: 0-30%VOL, 0.01%VOL, original imported industrial-grade anti-interference electrochemical principle sensor;
Project picture:






info@eranntexgas.com


13480931872