Shenzhen Eranntex Electronics Co., Ltd

首页> Cases

Gas Online Monitoring System Precision Storage Tank Ammonia Sulphur

1. Project Background


Keywords: Retention Pond, Hydrogen Sulfide, Ammonia, Temperature


Monitor ammonia and hydrogen sulfide levels, as well as temperature, within the retention p Ond.


AmbientTemperature, high humidity (gas drawn from the retention pond contains some moisture), normal press Ure, dust-free environment,


H2S: 0–25 ppm

< span>

NH3: 0-25 ppm


Temperature: -40°C to +120°C (actual gas temperature is ambient)


Testing Purpose: To verify the effectiveness of the client& #39;s own equipment in purifying hydrogen sulfide and ammonia.Results must be displayed to two decimal places.


2. Solution


Use a simple pre-trea Tment device to filter out moisture from the gas beFore measuring its concentration.


Pump-drawn system: gas From the retention pond is drawn through a pipeline for testing.


The product is installed outdoors with a stainLess steel housing and an IP67 protection rating.


3. Product Configuration


Product Model: TH1000-B-Y P


DetecTed gases: ammonia (NH3), hydrogen sulfide (H2S), and temperature


Detection range/resolution/detection principle:


NH3: 0–25 ppm, 0.01 ppm, electrochemical sensor with hYdrogen sulfide interference resistance;


H2S: 0–25 ppm, 0.01 ppm, electrochemical sensor;


Temperature: -40°C to +70°C, 0.1°C, capacitive sensor;


Equipped with an instrument housing made of S304 material, with a thickness of No less than 1.5 mm.


Includes a 10-meter flexible hose f Or connecting to ductwork and instruments,


Features an NPT 1/4-8 connector (S304).


Instrument protection rating: IP67.


four. On-site photos


picture3.png


Related Cases

Professional engineer

24-hour online serviceSubmit your needs and quickly recommend the right products for you

13480931872