At present, the increasingly complex atmospheric pollution situation is posing new challenges to the traditional method of monitoring atmospheric pollution sources. The current number of monitoring points of the environmental air national control point monitoring system is limited and the cost is high. The method of point replacement leads to insufficient timeliness, which fails to achieve the goal of refined control, and cannot achieve the ability of spatial and temporal dynamic trend analysis, pollution emission reduction evaluation, pollution source tracking, environmental early warning and forecasting in the monitoring system. In-depth excavation.
In combination with the requirements of the General Office of the State Council on the construction of ecological environment monitoring network, Yiyuntian has developed a set of low-cost, multi-parameter integrated compact micro-environmental air monitoring system that can achieve high-density grid layout with rich experience in the field of gas detection, and the grid monitoring system can fully cover the monitoring. Measure the area, and realize atmospheric pollution monitoring with high space-time resolution. At the same time, combined with the application of information big data, it realizes the functions of pollution source tracking, early warning and forecasting, etc., providing more timely and effective decision-making support for environmental pollution prevention and control.
TH2000-W micro-environmental air monitoring system is mainly composed of gaseous pollutant detection module, particulate matter detection module, meteorological parameter sensor, wireless communication module, power supply and power supply management listComponents, etc., and the monitoring factors include VOCs, SO2, NO2, CO, O3, PM10, PM2.5, temperature, humidity, wind speed and wind direction.
Design monitoring items: VOCs, SO2, NO2, CO, O3, PM10, PM2.5, temperature, humidity, wind speed, wind direction, detection factors are optional.
Product parameters:
Measurement range:
SO2: Electrochemical principle, 0-1ppm , resolution 0.01ppm or 0.001ppm, optional
NO2: Electrochemical principle, 0-1ppm, 0-1ppm, resolution 0.01ppm or 0.001ppm, optional
CO: Electrochemical principle, 0-1ppm, 0-1ppm, discrimination Rate 0.01ppm or 0.001ppm, optional
VOC: PID principle, 0-1ppm, 0-100ppm, resolution 0.01ppm or 0-10ppm, resolution 0.001ppm, optional
PM2.5: laser scattering principle, 0-500 micrograms/cubic, resolution 1 micrograms/cubic
PM10: Laser scattering principle, 0-500 micrograms/cubic, resolution 1 micrograms/cubic
Wind speed: 0-30 meters\seconds
Wind direction: 0-360 degrees
Temperature: -40-100 degrees
Humidity: 0-100%RH
Working environment: - 40℃~70℃, ≤95%RH
Work Mode: Online continuous work
Working voltage: 220VAC, 50HZ, optional solar power supply scheme
Output signal: 4~20mA, R S485, multiplex passive contacts, optional: wireless transmission 433, LORA, GPRS, NB-LOT, network transmission, etc.
Dimensions: 800mm high * 500mm wide * 340mm thick
Protection level: IP66 outdoor waterproof type, optional explosion-proof type
< Br/> Display mode: The standard product is a window display, which can be optionally equipped with 2.5-inch or 9-inch touch color screen display, linux operating system
Data storage: 100,000 data, optional 16G large-capacity S D memory card, USB disk storage