ammonia alarm installation should pay attention to what?
Publication Date:2021/07/19 ammonia alarm is a high-tech electronic product applied to ammonia detection and alarm. when it detects that the concentration of gas in the environment reaches or exceeds the preset alarm value, the ammonia alarm will transmit the signal to the controller through the shielded cable, and the controller will immediately send out sound and light alarm. at the same time, it can start the exhaust device or close the solenoid valve to cut off the gas source to achieve the purpose of safety. However, if you want the ammonia alarm to be used effectively, its installation is also a top priority. What should I pay attention to when installing ammonia alarm ? The following is a brief introduction by yi yun Tian:
Notes for Ammonia Alarm Installation:
1. The ammonia alarm probe is mainly a detection element that contacts the combustion gas sensor. It is composed of a platinum wire coil wrapped with alumina and adhesive, and its outer surface is attached with rare metals such as platinum and palladium. Therefore, be careful when installing to avoid breaking the probe.
2. the installation height of ammonia alarm should generally be 160-170cm to facilitate daily maintenance by maintenance personnel.
3. ammonia alarm is a safety instrument with sound and light display functions. it should be installed in a place where it is easy for staff to see and hear, so as to eliminate hidden dangers in time.
4. There should be no strong electromagnetic field (such as high-power motor and transformer) around the ammonia alarm that affects the operation of the instrument.
5. The density of the measured gas is different, and the installation position of the indoor probe should also be different. When the measured gas density is less than the air density, the probe should be installed 30cm away from the roof, with the direction downward; On the contrary, the probe should be installed 30cm away from the ground, with the direction upward.
In summary, it is the precautions for the installation of the ammonia alarm.In order to ensure safety, the ammonia alarm probe should be selected within a radius of 1 meter near the valve, pipeline interface, air outlet or leakage-prone place, as close as possible, but do not affect the operation of other equipment, and try to avoid high temperature and high humidity environment, but the specific installation position should be determined according to the specific gravity of the detected gas relative to the air.
Related information
-
Yiyuntian Eranntex Portable 4-in-1 Gas Detectors: Enhancing On-Site Safety Management for Petrochemical Production Enterprises!
The petrochemical industry involves numerous production processes and complex operational scenarios. Areas such as plant facilitie...
2026-04-30 -
Yiyuntian Eranntex Invites You to the 2026 Shanghai Emergency Response and Disaster Reduction Expo
As spring draws to a close, Shanghai is set to host a major event. From May 7 to 9, 2026, the 5th Yangtze River Delta Internationa...
2026-04-29 -
Application of Yiyuntian gas detector: accurate control of gas concentration to avoid accidents
The explosion accident of Weifang Gaomi Chemical Plant once again reminds us with the lesson of blood that there is no room for sl...
2025-06-06 -
Dust explosion hidden danger? Yiyuntian industrial explosion-proof dust detector to save the field!
With its excellent technical performance, Yiyuntian industrial explosion-proof dust detector has become a key weapon to crack the ...
2025-06-04 -
Breaking the game: Yiyuntian online dust detector to resolve the dilemma of CGNPC dust monitoring
Recently, CGN has encountered unprecedented challenges when promoting the new online dust detector project. The particularity of t...
2025-06-03
















info@eranntexgas.com


13480931872