Common Faults and Solutions of Combustible Gas Alarm
Publication Date:2021/11/22 In order to effectively prevent explosions, fires, and poisoning accidents and ensure safe production, it is currently required to install combustible gas alarms. Its gas alarm is the 1 kind of gas leakage detection and alarm instrument. When combustible gas leakage occurs in industrial environment, when the combustible gas alarm detects that the gas concentration reaches the critical point of explosion or the alarm setting, it will send out an alarm signal to remind the staff to take safety measures. However, during the use of combustible gas alarm , we will inevitably encounter some malfunctions.

combustible gas alarm common faults and solutions:
1. the false alarm of the combustible gas alarm
>
Reason: combustible gas alarm aging .
Solution: Re-calibrate and replace the alarm with a new one.
2. combustible gas alarm display panel does not display during use
Reasons: the power supply voltage of the instrument is abnormal, the display screen of the instrument may be flooded, and the circuit board is faulty .
Solution: Check the safety and the wiring connecting the instrument. Clean the instrument circuit board and dry it. After determining the damage, replace the battery board and replace the new instrument.
3. combustible gas alarm shows a large concentration value
reason: when the combustible gas alarm is calibrated, the standard gas concentration does not meet the requirements, and the sensor is aging.
Solution: Use qualified standard gas for calibration and replace with a new combustible gas alarm.
4. combustible gas alarm does not indicate 0 in normal environment
Solution: Re-calibrate the zero value under clean air, disassemble the sensor shield to clean up dust, and replace it with a new combustible gas alarm.
To sum up, it is the common fault and solution of combustible gas alarm. When we encounter some minor faults in the combustible gas alarm, we must pay attention to check the cause and analyze it, so as to solve the root cause. Only in this way can it be better to ensure that the combustible gas alarm can be used normally.
Related information
-
Yiyuntian Eranntex 5th Yangtze River Delta Emergency Expo Concludes Successfully
As late spring arrived in Shanghai, the grand event came to a close. From May 7 to 9, 2026, the 5th Yangtze River Delta Internatio...
2026-05-11 -
Yiyuntian Eranntex exhibits made their debut at the 2026 Shanghai Emergency Response and Disaster Reduction Expo, drawing massive crowds
On May 7, 2026, the 5th Yangtze River Delta International Emergency, Disaster Reduction, and Rescue Expo (EDRR) grandly opened at ...
2026-05-08 -
Yiyuntian Eranntex Portable 4-in-1 Gas Detectors: Enhancing On-Site Safety Management for Petrochemical Production Enterprises!
The petrochemical industry involves numerous production processes and complex operational scenarios. Areas such as plant facilitie...
2026-04-30 -
Yiyuntian Eranntex Invites You to the 2026 Shanghai Emergency Response and Disaster Reduction Expo
As spring draws to a close, Shanghai is set to host a major event. From May 7 to 9, 2026, the 5th Yangtze River Delta Internationa...
2026-04-29 -
Application of Yiyuntian gas detector: accurate control of gas concentration to avoid accidents
The explosion accident of Weifang Gaomi Chemical Plant once again reminds us with the lesson of blood that there is no room for sl...
2025-06-06
















info@eranntexgas.com sale1@eranntexgas.com


15914124845