How to clean the Voc gas detector
Publication Date:2020/04/15& nbsp; & nbsp; & nbsp; Now, many factories have installed VOC gas detectors, but do you know how gas detection cleaning is carried out? You may think that everyone understands this way. Please share
1, clean
if necessary, please wipe the equipment shell with a soft and clean cloth. You can't use solvents and detergents.
2, replace the sensor
To replace the sensor in the detector, first make sure that the ATM921 sampling pump is disconnected from the component.
3, Battery Charging
Before using the tester, fully charge the lithium battery box.

Precautions for routine maintenance of gas detector:
1. Comprehensive machine inspection: usually check the detector regularly.
2. Sensor maintenance: usually re-check the calibration between 6 months and 1 year after installation, and the inspector will fill in the test report.
3. The sensor of the gas sensor must be replaced when it loses its sensitivity. Regularly calibrate to determine whether the sensor is faulty. If the correction value does not reach the standard gas value, replace the sensor.
Precautions for daily use of the gas detector:
1. The VOC detector is tested in the normal working environment, and the working life of the sensor is more than 2 years.
2. In order to ensure the measurement accuracy, portable gas detectors need to be calibrated regularly for more than one year.
3. Prevent the portable gas detector from being exposed to high-concentration gas above the detection range. It is strictly prohibited to collide or the working life of the sensor may be lost.
4. in the absence of corrosive gases, fumes, dust, portable gas detector should be used.
5. If the machine does not respond for a long time, please turn off the power of the portable gas detector and restart it.
6. Prevent the portable VOC detector from falling from a height or vibrating violently.
Related information
-
Yiyuntian Eranntex Portable 4-in-1 Gas Detectors: Enhancing On-Site Safety Management for Petrochemical Production Enterprises!
The petrochemical industry involves numerous production processes and complex operational scenarios. Areas such as plant facilitie...
2026-04-30 -
Yiyuntian Eranntex Invites You to the 2026 Shanghai Emergency Response and Disaster Reduction Expo
As spring draws to a close, Shanghai is set to host a major event. From May 7 to 9, 2026, the 5th Yangtze River Delta Internationa...
2026-04-29 -
Application of Yiyuntian gas detector: accurate control of gas concentration to avoid accidents
The explosion accident of Weifang Gaomi Chemical Plant once again reminds us with the lesson of blood that there is no room for sl...
2025-06-06 -
Dust explosion hidden danger? Yiyuntian industrial explosion-proof dust detector to save the field!
With its excellent technical performance, Yiyuntian industrial explosion-proof dust detector has become a key weapon to crack the ...
2025-06-04 -
Breaking the game: Yiyuntian online dust detector to resolve the dilemma of CGNPC dust monitoring
Recently, CGN has encountered unprecedented challenges when promoting the new online dust detector project. The particularity of t...
2025-06-03
















info@eranntexgas.com


13480931872