What is the cause of the problem with the gas alarm?

Publication Date:2021/05/24

The reason for the problem of the gas alarm is very complicated, so the relevant technical personnel of the manufacturer should be contacted first after the problem occurs. Repair under the guidance of professionals or directly ask professionals to repair. So, what are the reasons for the gas alarm problems? The following is a small part of the cloud for you to introduce in detail, I hope to help you.



gas alarm controller

& nbsp;

gas alarm the reasons for the problem are as follows:

& nbsp;

standard sample gas detection has no response: when the gas alarm is checked regularly, the standard sample gas is introduced, and the meter shows no response. there are many reasons for this failure, which can be summarized as follows: sintered metal hole blockage, improper range setting, aging damage of components, circuit board damage; filter blockage, etc.

& nbsp;

improper use: during the use of the gas alarm, it may cause the resistivity of the platinum wire of the gas alarm to change and cause errors. during the use of the gas alarm, attention should be paid to prevent electromagnetic interference. The installation position, installation angle, protective measures and system wiring of the gas alarm shall be protected from electromagnetic interference. In the process of using the gas alarm, attention should be paid to the factors that are easy to cause failure, such as dust, high temperature, humidity, etc.

& nbsp;

Slow response: The instrument responds slowly during calibration, usually due to sensor aging.The gas alarm is in the harsh environment of some combustible gas for a long time, which will inevitably cause the aging failure of the components, especially the catalytic material, thus causing the catalytic combustion reaction of the detection element to become increasingly slow. In addition, improper range adjustment may also cause slow response or poor indication.

& nbsp;

The alarm does not display: the power supply voltage is abnormal, the meter is flooded, and the circuit board is faulty.

& nbsp;

the causes of the problems with the gas alarm will be introduced here first. if these problems can be found in time and "suit the remedy to the case" and properly handled, our work efficiency will be greatly improved and a strong guarantee will be provided for the smooth development of verification work and the safe production of gas-using places.