What is the conventional measuring range of the four-in-one gas detector?
Publication Date:2022/11/08 I believe everyone knows that the emergence of the four-in-one gas detector effectively solves the perception of colorless and odorless dangerous gases, and better protects the lives of relevant operators. In order to better ensure safety, before using the four-in-one gas detector, we need to understand its range first, and then set the appropriate range value according to our actual situation. So do you know 4-in -1 gas detector what is the normal range? The following is a brief introduction by yi yun Tian:

4-in -1 gas detector general range, as follows:
in general, the conventional range of the four-in-one gas detector is: 0-1ppm, 5ppm, 10ppm, 20ppm, 50ppm, 100ppm, 200ppm, 500ppm, 1000ppm, 2000ppm, 5000ppm, 10000ppm, 50000ppm, 100%Lel 0-2% Vol, 5% Vol, 10% Vol, 30% Vol optional. Conventional oxygen selection 0-30% VOL, hydrogen sulfide selection 0-100PPM, carbon monoxide selection 0-1000PPM , combustible choice 0-100% LEL.
the resolutions corresponding to different measuring ranges are also different. the resolutions we often encounter are generally,. 01 ppm or 0.001ppm(0 ~ 1ppm);0.01ppm(0 ~ 100ppm);0.1ppm(0 ~ 999ppm);1ppm(1000ppm and above); 0.1%Vol(0 to 100%Vol) or 0.01%Vol(0 to 100%Vol);0.1% Lel(0 to 100% Lel). At present, the detection range of Yiyuntian's MS600 portable four-in-one gas detector is CO(0 ~ 1000ppm), H2S(0 ~ 100ppm), O2(0 ~ 30% Vol), Ex(0~100 LEL). Other ranges can be customized and you can choose according to your own needs.
To sum up, it is the conventional range of the four-in-one gas detector. By using four-in-one gas detectors in agriculture, chemical industry, construction, electric power, fire protection, natural gas, steel industry, petroleum and petrochemical, sewage treatment and other fields, we can well detect the concentration of 4 kinds of gases such as oxygen sulfide, carbon monoxide, oxygen, combustible gas, etc. When the concentration exceeds the alarm value, vibration and sound alarms can be provided to prompt the staff to take relevant safety measures and stay away from danger immediately.
Related information
-
How to Calibrate a Portable four-in-one Gas Detectors?
Portable four-in-one gas detectors are core protective equipment in the industrial safety field. However, sensors can experience z...
2026-09-18 -
What are the application scenarios for portable four-in-one gas detectors?
Portable four-in-one gas detectors typically monitor oxygen (O₂), flammable gas (LEL), carbon monoxide (CO), and hydrogen sulfide...
2026-09-16 -
Portable four-in-one Gas Detectors User Manual
The portable four-in-one gas detectors is a core piece of personal protective equipment (PPE) for ensuring the safety of personnel...
2026-09-14 -
Calibration Specifications for Ammonia gas Detectors
Calibration of ammonia gas detectors is a core step in ensuring their measurement accuracy and alarm reliability. However, ammonia...
2026-09-11 -
What is the appropriate installation height for an ammonia gas detectors?
Ammonia (NH₃) has a relative density of only 0.59, much lighter than air. This means that in the event of a leak, the gas will qu...
2026-09-09
















info@eranntexgas.com sale1@eranntexgas.com


15914124845