What are the main functions of the combustible gas alarm?

Publication Date:2022/12/07

At present, in daily life and in some industrial fields, the application of combustible gas alarm is inseparable. The combustible gas alarm is used to detect the concentration of combustible gas, detect the lower explosion limit concentration (percentage content) of single or multiple combustible gas, and send out portable equipment for alarm, so as to ensure that technicians can successfully detect gas in relatively unfavorable working environment. So do you know what the main functions of the Combustible Gas Alarm are? The following is an introduction by Yi Yuntian:



The combustible gas alarm has the following main functions:


1. Alarm function


when the following phenomena occur, the combustible gas alarm will have audible and visual alarm signals:


a) when the measured gas concentration exceeds the set level 1 (A1 low report) alarm value or level 2 (A2 high report) alarm value, the buzzer will announce successive sounds and the concentration alarm indicator will be on, the general alarm relay is closed and the A1 alarm relay or A2 alarm relay is closed.


B) when the combustible gas alarm connection gas detector circuit has defects, such as no signal output, transmission line disconnection, transmission line short circuit, combustible gas alarm gas detector signal output exceeds the measurement plan, the buzzer will announce successive sounds, one defect alarm indicator is on, the universal alarm relay is closed and the defect alarm relay is closed.


c) when the main power is cut off and the controller is powered by the standby power, when the standby power voltage is insufficient, the buzzer will announce successive sounds.


2. Self-test function


, combustible gas alarm shall take the initiative to check the function of indicator light and buzzer on its panel. The combustible gas alarm self-test menu also provides a functional self-test of the status indicator, buzzer and relay.


3. Parameter setting function


job parameters can be checked and corrected, including the current date/time, measurement planning, alarm values at all levels, channel shielding, etc.


4. Active switching between main and standby power


when the main power supply of the combustible gas alarm is cut off, can actively switch to standby power supply operation; when the main power supply is recovered, can actively switch to the main power supply operation; the operation status of the main and standby power supplies is indicated by indicator lights. When the main power supply is in operation, the standby power supply can be charged together, and the standby power supply will be actively changed to floating charging condition after overflow.


5. Alarm output control function


there are 4 common alarm output relays. Control of fire fighting equipment, ventilation equipment, alarm equipment or other useful equipment.


6. Current calibration function


combustible gas alarm calibrate the input 4mA and 20mA current signals, timely synchronization of signals is ensured.


7. Communication function


combustible gas alarm has RS485 interface, it is easy to transfer data to other control devices, computers, etc.


8. Other functions


Total number of channels flashing and alarming total number of flashes.


In summary, these are some of the main functions of combustible gas alarms. Combustible gas alarm host is the brain of the gas alarm system. After the host can always check the specific conditions of the detection point, such as whether the gas concentration exceeds the standard on site, the working condition on site, etc. Assuming that the site is out of order, it will declare sound and light alarm and link peripheral equipment, thus reducing the occurrence of incidents.