Shenzhen Eranntex Electronics Co., Ltd

首页> Technical Information>Gas Detection Knowledge

What should I do when a composite gas detector leaks?

Publication Date:2022/12/30

In the process of using the composite gas detector, sometimes due to various reasons, it will lead to leakage. If we do not take relevant measures when there is a gas leak in the composite gas detector, it will certainly have a certain impact on the safety of use. Do you know what to do when a Composite Gas Detector leaks? The following is a brief introduction by yi yun Tian:



Composite Gas Detector, the following treatment measures shall be taken:


1. when the composite gas detector sends out an early warning alarm, personnel shall be evacuated in time, and the leakage valve shall be closed, the leakage source shall be cut off, reasonable ventilation shall be carried out, and spray water shall be used for dissolution and dilution. At the same time, the diluted water must also enter the wastewater system for centralized treatment, and cannot be directly discharged to the sewer to prevent secondary pollution.


2. When the composite gas detector leaks, sufficient ventilation should be provided for the leakage site, and then special personnel should be arranged to overhaul the leakage point on site after re-detecting the site environment and ensuring safety, and after the valve is reopened, regular manual inspection and testing shall be carried out to ensure safety before personnel can be arranged to enter the site for production operations.


3. after the conventional composite gas detector is used for a long period of time, some work failures will occur. if dangerous gas leaks, personnel in the leaking contaminated area should be quickly evacuated to the windy place, immediately isolated and strictly restricted. Evacuate irrelevant personnel and set up guard area. Cut off the fire source, cut off the leakage gas source as much as possible, open all doors and windows, let it naturally ventilate, and accelerate the diffusion. If possible, send the leaked gas to an open area with an exhaust fan or install a suitable nozzle to burn it off.


To sum up, when the composite gas detector leaks, some treatment measures should be taken. Through these measures, we can better ensure the safety of operators and working environment.


Related information

Latest NewsMore+

Related InformationMore+

Professional engineer

24-hour online serviceSubmit your needs and quickly recommend the right products for you

13480931872