What is the problem that the ammonia gas detector cannot work normally after installation?
Publication Date:2023/05/26 In many areas where ammonia may be generated, because various uncertain factors may lead to some dangers, we need to install an ammonia detector for 24 hours without interruption to detect the change of ammonia concentration in real time. However, after we installed the ammonia detector, many friends will encounter the situation that the ammonia detector cannot work normally. Do you know why the ammonia detector does not work properly after installation? The following is a brief introduction by yi yun Tian:

Ammonia detector does not work properly after installation, as follows:
1. Selecting the wrong device
If the gas to be detected in the place to be tested is methane, however, the carbon monoxide detector was installed by mistake. After installation, the instrument cannot work normally.
2. Installation is not standard
Ammonia detector needs to be installed in the vicinity where toxic, harmful or combustible gases are liable to leak, it is also necessary to avoid being adjacent to the exhaust fan during installation. If it is not installed correctly, the leaked combustible, toxic and harmful gases cannot fully diffuse to the vicinity of the ammonia gas detector, so that the leakage danger cannot be detected by the ammonia gas detector in time, and it will be mistaken for the instrument not working properly.
3. Detect environmental impact
, too complex and diverse. Meet the humid, water, irritating gas detection environment, the work of the ammonia detector is a great influence. Part of the gas detector in the room, the use of good conditions, long life, low failure rate. Part of the gas detectors are in the field, and the detectors work in the open air throughout the year. The air-conditioning flow, especially the salt-doped seawater flow directly passes through the combustible gas detector, and the resistivity change may cause errors.
4. Not properly maintained
In summary, it is the possible reason why the ammonia detector cannot work normally after installation. Only the correct installation method of the oxygen detector can better ensure the normal operation of the ammonia detector. Therefore, in the process of installing the ammonia detector, we must carefully watch the relevant installation instructions.
Related information
-
What is the service life of a carbon monoxide detectors?
In industrial settings such as petrochemicals, steel smelting, and underground mines, carbon monoxide is a prime example of a toxi...
2026-05-06 -
How to Use a Carbon Monoxide Detectors
In modern industrial environments, carbon monoxide is an extremely common and insidious lethal threat. It is not only a byproduct ...
2026-04-27 -
How to Verify That the Calibration Process for Oxygen Detectors Complies with International Standards?
In critical scenarios such as industrial safety, confined space entry, fire emergency response, and medical support, the accuracy ...
2026-04-24 -
How often should combustible gas detectors be calibrated?
In high-risk industries such as oil and gas, chemicals, manufacturing, and confined space operations, combustible gas detectors se...
2026-04-22 -
Why Does a Four-in-One Detectors Not Respond After Powering On?
In industrial safety, confined space entry, or emergency response scenarios, a four-in-one detectors is a critical piece of equipm...
2026-04-21












info@eranntexgas.com


13480931872