Since most industrial environments may have a certain concentration of combustible gas, in order to avoid the harm to human body and production caused by excessive gas concentration, combustible gas alarm should be installed at the location where gas leakage may occur as far as possible. However, the combustible gas alarm belongs to a single or multiple gas detection instrument, which plays an accurate measurement role through the sensor during operation. Due to the existence of a large number of combustible gas in some industries, in order to avoid accidents, it is necessary to install the instrument according to the standard, and the installation of the instrument can not be installed at will, need to be installed according to some types. Then you know combustible gas alarm what are the installation standards and basis? The following is an introduction to yiyuntian electronic editor:


 combustible gas alarm


combustible gas alarm installation standard and basis:


1. according to articles 10, 3 and 2 of the GBJ16-87 code for fire protection design of buildings (revised edition 2001), there are class a factories or places emitting combustible gas and combustible vapor, combustible gas alarms shall be provided as per standard.


2. according to articles 4, 6 and 11 of the GB50160-92 "code for design of fire protection for petrochemical enterprises" (revised edition 99), in the use or production of class a gas or class a, B Class A liquid device can be in accordance with the combination of regional control and key control principle, set up combustible gas alarm probe.


3. according to articles 5, 1 and 4 of the GB50160-92 "code for fire protection design of petrochemical enterprises" (revised edition 99), when there may be leakage of class a gas or liquid in the production environment, combustible gas alarm shall be set up according to the standard.


In summary, the installation standards and basis of combustible gas alarms are various, including relevant national and local regulations and standards, specific working environment and usage scenarios, and regular maintenance and calibration. Only by strictly following these standards and basis can we ensure the accuracy and reliability of the combustible gas alarm and protect the industrial safety. Therefore, its installation work must strictly follow a series of standards and bases to ensure its accuracy and reliability.