What is the installation distance of the detection range of the oxygen detector?
Publication Date:2023/08/02 in some petroleum, petrochemical, chemical, gas, coal, metallurgy, electric power, municipal, telecommunications, traffic tunnel construction safety testing, electronics, semiconductor industry and other occasions using oxygen as raw materials, in order to better prevent oxygen leakage, it is necessary to carry out real-time on-line detection at the leakage point device oxygen detector, realize the safe operation of industrial oxygen, and avoid the harm of oxygen leakage. However, when we install the oxygen detector, there are also relevant standard requirements for its installation distance. Do you know the installation distance of the oxygen detector detection range? The following is a brief introduction by yi yun Tian:

installation range of oxygen detector:
1. the release source is located in the equipment area arranged in the open air or open plant. the horizontal distance between the combustible gas detector of the oxygen detector and any release source within its coverage area should not be greater than 10m, the horizontal distance between the toxic gas detector and any release source within its coverage should not be greater than 4m.
2. the release source is located in a closed plant or a semi-open plant with poor local ventilation. the horizontal distance between the combustible gas detector of the oxygen detector and any release source within its coverage should not be greater than 5m, the horizontal distance of the toxic gas detector from any release source within its coverage should not be greater than 2m.
In summary, we can see the installation distance of the detection range of the oxygen detector. Under normal circumstances, the outdoor distance should not exceed 4m, and the indoor distance should not exceed 2m, by using the oxygen detector, we can send out sound and light warning in time when oxygen leaks, remind personnel to evacuate and take measures to ensure the safety of production operations. Of course, we should also be combined with the actual situation needs to reasonably set the installation distance of the oxygen detector detection range.
Related information
-
What is the service life of a carbon monoxide detectors?
In industrial settings such as petrochemicals, steel smelting, and underground mines, carbon monoxide is a prime example of a toxi...
2026-05-06 -
How to Use a Carbon Monoxide Detectors
In modern industrial environments, carbon monoxide is an extremely common and insidious lethal threat. It is not only a byproduct ...
2026-04-27 -
How to Verify That the Calibration Process for Oxygen Detectors Complies with International Standards?
In critical scenarios such as industrial safety, confined space entry, fire emergency response, and medical support, the accuracy ...
2026-04-24 -
How often should combustible gas detectors be calibrated?
In high-risk industries such as oil and gas, chemicals, manufacturing, and confined space operations, combustible gas detectors se...
2026-04-22 -
Why Does a Four-in-One Detectors Not Respond After Powering On?
In industrial safety, confined space entry, or emergency response scenarios, a four-in-one detectors is a critical piece of equipm...
2026-04-21












info@eranntexgas.com


13480931872