Introduction to the working principle of ozone detector
Publication Date:2021/11/18 Ozone is 1 widely used gas, which exists in many industries, such as chemical, medical and pharmaceutical clean rooms, so it is necessary to detect the concentration of ozone in the environment. The ozone detector is currently mainly used for continuous detection of ozone gas in various industrial environments, and can also be used to detect the 1 gas detection of ozone gas in the environment such as pipelines and containers in operation. So do you know how the ozone detector works? The following is a brief introduction by yi yun Tian:

The working principle of the ozone detector:
1, electrochemical method
electrochemical method is the method of diffusion or pumping of the measured ozone gas and instrument contact, and react. Output a stable electrical signal. The gas concentration value can be stably displayed on the display screen with data. This method is simple and convenient to detect ozone, and can be measured as you take it.
2, ultraviolet absorption method
ozone detector adopts the principle of ultraviolet absorption method and uses stable ultraviolet lamp light source to generate ultraviolet rays, use a light wave filter to filter out other wavelengths of ultraviolet light, allowing only the wavelength of 253.7nm to pass. After the sample photoelectric sensor, and then through the ozone absorption cell, to reach the sampling photoelectric sensor.
the ozone detector uses the principle of ultraviolet spectrophotometry to measure ozone. when the air sample enters the gas path system of the instrument at a constant flow rate, the sample air alternately or directly enters the absorption tank or enters the absorption tank after passing through the ozone scrubber. ozone has a positive effect on 254nm The wavelength of ultraviolet light has a characteristic absorption, zero air sample, the light intensity detected by the light detector when passing through the absorption cell is I0, the light intensity detected by the light detector when the ozone sample passes through the absorption cell is I, and I/I0 is the light transmittance. After each cycle, the micro-processing system of the instrument calculates the concentration of ozone according to Lambert-Beer's law.
In summary, it is the working principle of the ozone detector. In fact, the principle of ozone concentration is to use chemiluminescence, ultraviolet absorption and electrochemical method. However, due to the chemiluminescence method must be equipped with ethylene cylinders, ethylene is combustible, both dangerous and inconvenient, so in recent years, the commonly used ultraviolet absorption method and electrochemical method.
Related information
-
How to Calibrate a Portable four-in-one Gas Detectors?
Portable four-in-one gas detectors are core protective equipment in the industrial safety field. However, sensors can experience z...
2026-09-18 -
What are the application scenarios for portable four-in-one gas detectors?
Portable four-in-one gas detectors typically monitor oxygen (O₂), flammable gas (LEL), carbon monoxide (CO), and hydrogen sulfide...
2026-09-16 -
Portable four-in-one Gas Detectors User Manual
The portable four-in-one gas detectors is a core piece of personal protective equipment (PPE) for ensuring the safety of personnel...
2026-09-14 -
Calibration Specifications for Ammonia gas Detectors
Calibration of ammonia gas detectors is a core step in ensuring their measurement accuracy and alarm reliability. However, ammonia...
2026-09-11 -
What is the appropriate installation height for an ammonia gas detectors?
Ammonia (NH₃) has a relative density of only 0.59, much lighter than air. This means that in the event of a leak, the gas will qu...
2026-09-09
















info@eranntexgas.com sale1@eranntexgas.com


15914124845