What is the alarm range of oxygen alarm?
Publication Date:2022/09/15 Oxygen is an essential element of the human body, and the oxygen content in the air is very important to the human body. In the general environment, the air inhaled by people accounts for 20.93 per cent of oxygen and 0.03 per cent of carbon dioxide by volume; in the exhaled air, carbon dioxide rises by about 3.5 per cent and oxygen falls by about 17 per cent. Although oxygen is an important part of air, it does not mean that it is non-toxic. Too low and too high oxygen content will cause certain hazards. Therefore, we need to install an oxygen alarm. Do you know what the Oxygen Alarm alarm range is? The following is a brief introduction by yi yun Tian:
normal human body only needs a certain concentration of oxygen, too high or too low oxygen concentration is harmful to human body:
oxygen concentration (% volume)-indication (at atmospheric pressure)
& gt;23.5-oxygen enrichment, danger of severe explosion
20.9-normal oxygen concentration
19.5-minimum allowable oxygen concentration
15-19% --- reduce work efficiency, it can lead to head, lung and circulatory problems
10-12% --- shortness of breath, loss of judgment, purple lips
8-10% --- loss of intelligence, fainting, unconscious, pale face, purple lips, nausea and vomiting
6-8%-fatal in 8 minutes;
4-6%-convulsions within 40 seconds, respiratory arrest, death
100-Fatal/6 min
50%-Fatal/4-5 min Healing
Therefore, under normal circumstances, the alarm range of oxygen alarm is generally 19.5 vol and 23% vol, and alarms will be given when the alarm is lower than 19.5 vol and higher than 23%. The measurement range of oxygen concentration value is generally 0-30% vol, and it is normal when the alarm range is between 19.5% and vol-23 vol.The oxygen alarm can be configured in the oxygen use place to detect the oxygen concentration on site in real time to ensure the safety of on-site personnel.
Related information
-
Accuracy Requirements for Carbon Dioxide Detectors
Amid the global industrial transformation driven by carbon neutrality goals, the accuracy of carbon dioxide detectors directly imp...
2026-05-08 -
What is the service life of a carbon monoxide detectors?
In industrial settings such as petrochemicals, steel smelting, and underground mines, carbon monoxide is a prime example of a toxi...
2026-05-06 -
How to Use a Carbon Monoxide Detectors
In modern industrial environments, carbon monoxide is an extremely common and insidious lethal threat. It is not only a byproduct ...
2026-04-27 -
How to Verify That the Calibration Process for Oxygen Detectors Complies with International Standards?
In critical scenarios such as industrial safety, confined space entry, fire emergency response, and medical support, the accuracy ...
2026-04-24 -
How often should combustible gas detectors be calibrated?
In high-risk industries such as oil and gas, chemicals, manufacturing, and confined space operations, combustible gas detectors se...
2026-04-22












info@eranntexgas.com


13480931872