I believe everyone knows that the oxygen detector is a key device to ensure the safety of oxygen concentration in the working environment, and its normal working state is essential to prevent safety hazards such as hypoxia or oxygen enrichment. Therefore, in order to ensure the safety of personnel and the smooth progress of production, it is particularly important to regularly check and judge the working status of the oxygen detector. So do you know how to tell if the oxygen detector is working properly? The following is an introduction to yiyuntian electronic editor:


 oxygen detector


Judging whether the oxygen detector is working normally can be done from the following aspects:


1. Appearance and Functionality Checks


Check the goods list: ensure that the oxygen detector, instructions, certificate, installation accessories, etc. are complete.


Check the appearance: Observe the oxygen detector for damage, deformation or stains, and ensure that it is not damaged during transportation or assembly.


Check the power supply: Make sure that the battery of the oxygen detector is properly installed and fully charged, or the charger is working properly and the charging interface is not damaged.


2. Power-on and Initialization Check

First power up: the initial power-on of the oxygen detector should be no less than 20 minutes to stabilize the sensor. After power-on, the sensor may have an alarm phenomenon, which is determined by the characteristics of the sensor itself. After waiting for the preheating/polarization, the sensor value will automatically return to the normal value.


Function check: Check whether the function buttons of the oxygen detector work normally and whether the page parameters are displayed correctly.


3. measurement accuracy and response checking


Standard Gas Test: if conditions permit, perform a ventilation test on the oxygen detector using a known concentration of standard oxygen. The response time and detection accuracy of the oxygen detector can be tested by using the corresponding standard gas according to the range. In general, it is normal that the indication error of oxygen is within ± 0.5 VOL.


Observe the reading changes: During the test, observe whether the reading of the oxygen detector is stable and whether there is obvious fluctuation or drift.


4. alarm function check


Set Alarm Threshold: according to the actual demand, the alarm threshold of the oxygen detector is set reasonably.


Alarm test: Test whether the alarm function of the oxygen detector is normal by adjusting the gas concentration or using standard gas. Alarm sounds, alarm indicator lights, etc. shall work normally.


5. routine maintenance and calibration

Periodic calibration: in order to ensure the performance of the sensor, it needs to be calibrated regularly. The calibration frequency is determined by the specific working conditions of the oxygen detector, and it is recommended to calibrate the sensor every 3 months.For the presence of high concentration impact, corrosive gases and other factors, the calibration cycle should be shortened accordingly.


Keep clean: regularly clean the sensor and protective cover of the oxygen detector to prevent blockage from causing the detection sensitivity Decreased or even damaged.


Record the inspection: Record the results of each calibration and inspection to track changes in the performance of the oxygen detector.


To sum up, we can see that through the appearance and function inspection, power-on and initialization inspection, measurement accuracy and response inspection, alarm function inspection, daily maintenance and calibration and other steps, we can fully judge whether the oxygen detector is working normally.At the same time, during use, operation and maintenance should be carried out in strict accordance with the requirements of the manual to ensure the accuracy and reliability of the oxygen detector.